Browse the corpus
Walk the Even Hospital Database by book and chapter — the raw source passages that ground Ask, DDx, and the rest.
6 passages
REFERENCES Chatoth DK, Golper TA, Gokal R. Morbidity and mortality in redefining adequacy of peritoneal dialysis: a step beyond the National Kidney Foundation Dialysis Outcomes Quality Initiative. Am J Kidney Dis 1999; 33:617. U.S. Renal Data System. USRDS 1995 Annual Report: Atlas of End-Stage Renal Disease in the United States, National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MD. Frankenfield DL, Prowant BF, Flanigan MJ, et al. Trends in clinical indicators of care for adult peritoneal dialysis patients in the United States from 1995 to 1997. ESRD Core Indicators Workgroup. Kidney Int 1999; 55:1998. US Renal Data System, USRDS 1999 Annual Data Report, The National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Disease, Bethesda, MD, August 1999. US Renal Data System, USRDS 2002 Annual Data Report, The National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Disease. Am J Kidney Dis 2003; 41(Suppl 2):S91. US Renal Data System, USRDS 2009 Annual Data Report, The National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Disease. Am J Kidney Dis 2010; 55(Suppl 1):S1. Gokal R, Jakubowski C, King J, et al. Outcome in patients on continuous ambulatory peritoneal dialysis and haemodialysis: 4-year analysis of a prospective multicentre study. Lancet 1987; 2:1105. Oreopoulos DG. The optimization of continuous ambulatory peritoneal dialysis. Kidney Int 1999; 55:1131. Rottembourg J. Residual renal function and recovery of renal function in patients treated by CAPD. Kidney Int Suppl 1993; 40:S106. Blake PG. What is the problem with high transporters? Perit Dial Int 1997; 17:317. Coles GA. Have we underestimated the importance of fluid balance for the survival of PD patients? Perit Dial Int 1997; 17:321. Brown EA, Davies SJ, Rutherford P, et al. Survival of functionally anuric patients on automated peritoneal dialysis: the European APD Outcome Study. J Am Soc Nephrol 2003; 14:2948. Oreopoulos, DG. Criteria for adequacy of peritoneal dialysis. Perit Dial Bull 1983; 3:1. Teehan BP, Schleifer CR, Brown J. Adequacy of continuous ambulatory peritoneal dialysis: morbidity and mortality in chronic peritoneal dialysis. Am J Kidney Dis 1994; 24:990.
Brown EA, Davies SJ, Rutherford P, et al. Survival of functionally anuric patients on automated peritoneal dialysis: the European APD Outcome Study. J Am Soc Nephrol 2003; 14:2948. Oreopoulos, DG. Criteria for adequacy of peritoneal dialysis. Perit Dial Bull 1983; 3:1. Teehan BP, Schleifer CR, Brown J. Adequacy of continuous ambulatory peritoneal dialysis: morbidity and mortality in chronic peritoneal dialysis. Am J Kidney Dis 1994; 24:990. Keshaviah P. Urea kinetic and middle molecule approaches to assessing the adequacy of hemodialysis and CAPD. Kidney Int Suppl 1993; 40:S28. Nolph, KD. Quantitating peritoneal dialysis delivery: A required standard of care. Semin Dial 1991; 4:139. Adequacy of dialysis and nutrition in continuous peritoneal dialysis: association with clinical outcomes. Canada-USA (CANUSA) Peritoneal Dialysis Study Group. J Am Soc Nephrol 1996; 7:198. Bargman JM, Thorpe KE, Churchill DN, CANUSA Peritoneal Dialysis Study Group. Relative contribution of residual renal function and peritoneal clearance to adequacy of dialysis: a reanalysis of the CANUSA study. J Am Soc Nephrol 2001; 12:2158. Diaz-Buxo JA, Lowrie EG, Lew NL, et al. Associates of mortality among peritoneal dialysis patients with special reference to peritoneal transport rates and solute clearance. Am J Kidney Dis 1999; 33:523. Termorshuizen F, Korevaar JC, Dekker FW, et al. The relative importance of residual renal function compared with peritoneal clearance for patient survival and quality of life: an analysis of the Netherlands Cooperative Study on the Adequacy of Dialysis (NECOSAD )-2. Am J Kidney Dis 2003; 41:1293. Paniagua R, Amato D, Vonesh E, et al. Effects of increased peritoneal clearances on mortality rates in peritoneal dialysis: ADEMEX, a prospective, randomized, controlled trial. J Am Soc Nephrol 2002; 13:1307. Paniagua R, Amato D, Vonesh E, et al. Health-related quality of life predicts outcomes but is not affected by peritoneal clearance: The ADEMEX trial. Kidney Int 2005; 67:1093. Lo WK, Ho YW, Li CS, et al. Effect of Kt/V on survival and clinical outcome in CAPD patients in a randomized prospective study. Kidney Int 2003; 64:649. Szeto CC, Wong TY, Chow KM, et al. Independent effects of renal and peritoneal clearances on the mortality of peritoneal dialysis patients. Perit Dial Int 2004; 24:58.
Paniagua R, Amato D, Vonesh E, et al. Health-related quality of life predicts outcomes but is not affected by peritoneal clearance: The ADEMEX trial. Kidney Int 2005; 67:1093. Lo WK, Ho YW, Li CS, et al. Effect of Kt/V on survival and clinical outcome in CAPD patients in a randomized prospective study. Kidney Int 2003; 64:649. Szeto CC, Wong TY, Chow KM, et al. Independent effects of renal and peritoneal clearances on the mortality of peritoneal dialysis patients. Perit Dial Int 2004; 24:58. Lo WK, Lui SL, Chan TM, et al. Minimal and optimal peritoneal Kt/V targets: results of an anuric peritoneal dialysis patient's survival analysis. Kidney Int 2005; 67:2032. Jansen MA, Termorshuizen F, Korevaar JC, et al. Predictors of survival in anuric peritoneal dialysis patients. Kidney Int 2005; 68:1199. Lam MF, Tang C, Wong AK, et al. ASPD: A prospective study of adequacy in Asian patients on long term, small volume, continuous ambulatory peritoneal dialysis. Perit Dial Int 2006; 26:466. Moran J, Correa-Rotter R. Revisiting the peritoneal dialysis dose. Semin Dial 2006; 19:102. K/DOQI Clinical Practice Guidelines for Peritoneal Dialysis Adequacy. Am J Kidney Dis 2006; 47(Suppl 4):S1. European Best Practice Guidelines for peritoneal dialysis. Nephrol Dial Transplant 2005; 20(Suppl 9):1. Lo WK, Bargman JM, Burkart J, et al. Guideline on targets for solute and fluid removal in adult patients on chronic peritoneal dialysis. Perit Dial Int 2006; 26:520. Brandes JC, Piering WF, Beres JA, et al. Clinical outcome of continuous ambulatory peritoneal dialysis predicted by urea and creatinine kinetics. J Am Soc Nephrol 1992; 2:1430. Twardowski ZJ. PET--a simpler approach for determining prescriptions for adequate dialysis therapy. Adv Perit Dial 1990; 6:186. Brimble KS, Walker M, Margetts PJ, et al. Meta-analysis: peritoneal membrane transport, mortality, and technique failure in peritoneal dialysis. J Am Soc Nephrol 2006; 17:2591. Davies, SJ. Mitigating peritoneal membrane characteristics in modern peritoneal dialysis therapy. Kid Int 2006; 70:S76. Yang X, Fang W, Bargman JM, Oreopoulos DG. High peritoneal permeability is not associated with higher mortality or technique failure in patients on automated peritoneal dialysis. Perit Dial Int 2008; 28:82.
Davies, SJ. Mitigating peritoneal membrane characteristics in modern peritoneal dialysis therapy. Kid Int 2006; 70:S76. Yang X, Fang W, Bargman JM, Oreopoulos DG. High peritoneal permeability is not associated with higher mortality or technique failure in patients on automated peritoneal dialysis. Perit Dial Int 2008; 28:82. Churchill DN, Thorpe KE, Nolph KD, et al. Increased peritoneal membrane transport is associated with decreased patient and technique survival for continuous peritoneal dialysis patients. The Canada-USA (CANUSA) Peritoneal Dialysis Study Group. J Am Soc Nephrol 1998; 9:1285. Rumpsfeld M, McDonald SP, Johnson DW. Higher peritoneal transport status is associated with higher mortality and technique failure in the Australian and New Zealand peritoneal dialysis patient populations. J Am Soc Nephrol 2006; 17:271. Davies SJ. Mitigating peritoneal membrane characteristics in modern peritoneal dialysis therapy. Kidney Int Suppl 2006; :S76. Nolph KD. What's new in peritoneal dialysis--an overview. Kidney Int Suppl 1992; 38:S148. Tzamaloukas AH, Murata GH, Malhotra D, et al. Urea kinetic modeling in continuous peritoneal dialysis patients. Effect of body composition on the methods for estimating urea volume of distribution. ASAIO J 1993; 39:M359. Tzamaloukas AH, Malhotra D, Murata GH. Indicators of body size in peritoneal dialysis: their relation to urea and creatinine clearances. Perit Dial Int 1998; 18:366. Lameire NH, Vanholder R, Veyt D, et al. A longitudinal, five year survey of urea kinetic parameters in CAPD patients. Kidney Int 1992; 42:426. Lameire N, Van Biesen W. The impact of residual renal function on the adequacy of peritoneal dialysis. Perit Dial Int 1997; 17 Suppl 2:S102. Keshaviah PR, Emerson PF, Nolph KD. Timely initiation of dialysis: a urea kinetic approach. Am J Kidney Dis 1999; 33:344. Twardowski ZJ. Relationships between creatinine clearances and Kt/V in peritoneal dialysis patients: a critique of the DOQI document. Dialysis Outcome Quality Initiative, National Kidney Foundation. Perit Dial Int 1998; 18:252. Meyer, KV, Venkataraman, V, Twardowski, ZJ. Creatine kinetics in peritoneal dialysis. Semin Dial 1998; 11:88. Blake P, Burkart JM, Churchill DN, et al. Recommended clinical practices for maximizing peritoneal dialysis clearances. Perit Dial Int 1996; 16:448.
Twardowski ZJ. Relationships between creatinine clearances and Kt/V in peritoneal dialysis patients: a critique of the DOQI document. Dialysis Outcome Quality Initiative, National Kidney Foundation. Perit Dial Int 1998; 18:252. Meyer, KV, Venkataraman, V, Twardowski, ZJ. Creatine kinetics in peritoneal dialysis. Semin Dial 1998; 11:88. Blake P, Burkart JM, Churchill DN, et al. Recommended clinical practices for maximizing peritoneal dialysis clearances. Perit Dial Int 1996; 16:448. Clinical Practice Guidelines of the Canadian Society of Nephrology for the Treatment of Patients with Chronic Renal Failure. J Am Soc Nephrol 1999; 10:S13. The Renal Association and Royal College of Physicians of London. Treatment of adult patients with renal failure: Recommended standards and audit measures. Royal College of Physicians, London 1997. Chung SH, Heimbürger O, Stenvinkel P, et al. Influence of peritoneal transport rate, inflammation, and fluid removal on nutritional status and clinical outcome in prevalent peritoneal dialysis patients. Perit Dial Int 2003; 23:174. Harty JC, Boulton H, Venning MC, Gokal R. Is peritoneal permeability an adverse risk factor for malnutrition in CAPD patients? Miner Electrolyte Metab 1996; 22:97. Jones CH, Wells L, Stoves J, et al. Can a reduction in extracellular fluid volume result in increased serum albumin in peritoneal dialysis patients? Am J Kidney Dis 2002; 39:872. Dumler F. Hypoalbuminemia is a marker of overhydration in chronic maintenance patients on dialysis. ASAIO J 2003; 49:282. Ate�� K, Nergizo��lu G, Keven K, et al. Effect of fluid and sodium removal on mortality in peritoneal dialysis patients. Kidney Int 2001; 60:767. Davies SJ, Brown EA, Reigel W, et al. What is the link between poor ultrafiltration and increased mortality in anuric patients on automated peritoneal dialysis? Analysis of data from EAPOS. Perit Dial Int 2006; 26:458. Woodrow G. Methodology of assessment of fluid status and ultrafiltration problems. Perit Dial Int 2007; 27 Suppl 2:S143. Konings CJ, Kooman JP, van der Sande FM, Leunissen KM. Fluid status in peritoneal dialysis: what's new? Perit Dial Int 2003; 23:284. Warren PJ, Brandes JC. Compliance with the peritoneal dialysis prescription is poor. J Am Soc Nephrol 1994; 4:1627.
Woodrow G. Methodology of assessment of fluid status and ultrafiltration problems. Perit Dial Int 2007; 27 Suppl 2:S143. Konings CJ, Kooman JP, van der Sande FM, Leunissen KM. Fluid status in peritoneal dialysis: what's new? Perit Dial Int 2003; 23:284. Warren PJ, Brandes JC. Compliance with the peritoneal dialysis prescription is poor. J Am Soc Nephrol 1994; 4:1627. Burkart JM, Bleyer AJ, Jordan JR, Zeigler NC. An elevated ratio of measured to predicted creatinine production in CAPD patients is not a sensitive predictor of noncompliance with the dialysis prescription. Perit Dial Int 1996; 16:142. Nolph KD, Twardowski ZJ, Khanna R, et al. Predicted and measured daily creatinine production in CAPD: identifying noncompliance. Perit Dial Int 1995; 15:22. Szeto CC, Lai KN, Wong TY, et al. Measured-to-predicted creatinine generation ratio increases with time and decline in residual renal function in continuous ambulatory peritoneal dialysis. Am J Kidney Dis 1999; 34:235. Stojimirovic BB, Blake PG, Oreopoulos DG. Assessing compliance with peritoneal dialysis. Int J Artif Organs 2001; 24:591. Sarkar S, Bernardini J, Fried L, et al. Tolerance of large exchange volumes by peritoneal dialysis patients. Am J Kidney Dis 1999; 33:1136. Topic 1968 Version 10.0 © 2013 UpToDate, Inc. All rights reserved. | Subscription and License Agreement | Release: 21.3 - C21.34 Licensed to: Morehouse School of Medicine | Support Tag: [1002-210.101.131.232-2A3F076F4F-S473950.14]